Gas Analyzers​

> Gas Chromatographs​
> Moisture
> Oxygen (Fixed)
Thermal Conductivity

> Hydrocarbon
> Nitrogen
> Oxygen (Portable​)
> Tunable Diode Laser

​> Infrared
Nitrogen Oxides / Ammonia
> Sulfur
> Ultraviolet​


Gas Chromat​​ographs​

​​​​
​Model Description ​Detectors


Falcon GC​

Ultra-Fast Gas Chromatograph for Process and Lab Applications

• Aspiration to inlet via sample pump​
​• Process online via sample valve for         gas or liquid*
• Autosampler injections for liquid or       heated headspace
• Manual sy​ringe injection for gas or          liquid​

*Sample handling available

Dielectric Barrier Discharge (DBD)
​Flame Ionization (FID)
Flame Photometric (FPD)
Thermal Conductivity (TCD)


​4000 Series​​

Ultra-Fast Rack-Mount Gas Chromatograph

• Process online via sample valve for         gas and aspiration

Dielectric Barrier Discharge (DBD)
Flame Ionization (FID)
Flame Photometric (FPD)
Thermal Conductivity (TCD)​


4040

Methane / Non-Methane Gas Chromatograph

​Flame Ionization (FID)

4060​

Gas Chromatograph

​Flame Ionization (FID)
Plasma Emission Detector (PED)​
Thermal Conductivity (TCD)

​​Back to Top​​​​


 ​​Hydrocarbon Analyzers ​ ​ ​
​Model ​Configuration ​Range(s)


4020​Total Hydrocarbon ​ Analyzer
​0-10, 0-100, 0-1,000 ppm THC standard
Other ranges including down to 0-1ppm available
​4030​Total Hydrocarbon Analyzer
semi-continuous for heated or ambient samples
​​0-10, 0-100, 0-1,000 ppm THC standard
Other ranges including down to 0-1ppm available


Infrared Analyzers ​ ​ ​

​ModelTechnology
​Gases ​Range(s)

​5000B
​​​Near Infrared (NIR) Absorption​​​
​​Contact Factory
​Three user selectable ranges
5020​
​Near Infrared (NIR) Absorption​​​
​​Contact Factory
​Three user selectable ranges

5020IR​

​​Near Infrared (NIR) Absorption​​
​Contact Factory
ppm to Percent 
Application-Dependent

6020L
​​Tunable Diode Laser Spectroscopy (TDLAS)
Carbon Dioxide (CO2)
​Hydrogen Sulfide (H2S)

0-100 ppm to 0-100%
​0-10 ppm to 0-20%
​​

​7300A​
​​Non-Dispersive
Infrared (NDIR)
Carbon Dioxide (CO2)    
Carbon Monoxide (CO)         
Methane (CH4)          
C2 to C5   
0-1% to 0-100%
0-5% to 0-100%
0-10% to 0-100%
0-5% to 0-100%
7300B​
​​Non-Dispersive
Infrared (NDIR)
Carbon Dioxide (CO2)    
Carbon Monoxide (CO)         
Methane (CH4)          
C2 to C5   
0-1% to 0-100%
0-5% to 0-100%
0-10% to 0-100%
0-5% to 0-100%

7320​
​Non-Dispersive
Infrared (NDIR)
Carbon Dioxide (CO2)    
Carbon Monoxide (CO)        
Methane (CH4)          
C2 to C5   
0-1% to 0-100%
0-5% to 0-100%
0-10% to 0-100%
0-5% to 0-100%






​7500ZA / 7500ZB​Non-Dispersive
Infrared (NDIR)
Carbon Dioxide(CO2)
Carbon Monoxide (CO)
Methane (CH4)
Nitric Oxide (NO)
Oxygen (O2) (fuel cell)
Oxygen (O2​) ​(paramagnetic)
Sulfur Dioxide (SO2)
0-100 ppm to 0-100%
0-200 ppm to 0-100%
0-500 ppm to 0-100%
​0-200 ppm to 0-5,000 ppm
0-10% to 0-25%
0-5% to 0-100% (7500ZA)
​0-200 ppm to 0-10%
​7600ZA /​ 7600ZB​Non-Dispersive Infrared (NDIR)
Carbon Dioxide(CO2)
Carbon Monoxide (CO)
Nitric Oxide (NO)
Oxygen (O2) (fuel cell)
Oxygen (O2​) ​(paramagnetic)
Sulfur Dioxide (SO2)
0-50 ppm to 0-25%
0-50 ppm to 0-5,000 ppm
​0-50 ppm to 0-5,000 ppm
0-10% to 0-25%
0-5% to 0-100%

0-50 ppm to 0-5,000 ppm
​7600ZAXL
​Non-Dispersive Infrared (NDIR)
Carbon Dioxide(CO2)
Carbon Monoxide (CO)
Nitric Oxide (NO)
Oxygen (O2) (fuel cell)
Oxygen (O2​) ​(paramagnetic)​
Sulfur Dioxide (SO2)
0-5 ppm to 0-50 ppm
0-5 ppm to 0-50 ppm
0-10 ppm to 0-100 ppm
0-10% to 0-25%
0-5% to 0-100%

0-10 ppm to 0-100 ppm​

8800L
​​Tunable Diode Laser Spectroscopy (TDLAS)
​Moisture (H2Ov)
​0-5 ppm to 0-2,500 ppm





​​
​GFC-7000T​​Infrared Absorption with Gas Filter Correlation
Carbon Dioxide (​CO2)
​0-2 ppm to 0-2,000 ppm 
(0-100 ppb to 0-100 ppm for -U version)
(dual ranges and auto ranging supported)
​GFC-7001TInfrared Absorption with Gas Filter Correlation
Carbon Monoxide (​CO)
​0-1 ppm to 0-1,000 ppm 
(0-100ppb to 0-100ppm ​for-U version)
(dual ranges and auto ranging supported)
GFC-7002T​Infrared Absorption with Gas Filter Correlation
​Nitrous Oxide (N2O)
​0-1 ppm to 0-1,000 ppm
(0-200 ppb to 0-200 ppm​ for -U version)
(dual ranges and auto ranging supported)


Moisture Analyzers ​ ​ 

​Model Technology ​Range(s)

8800A​
​Aluminum Oxide (Al2O3)
​-100°C to +20°C dew-point

8800B
​Aluminum Oxide (Al2O3)
​-100°C to +20°C dew-point

​8800P​

​Aluminum Oxide (Al2O3)
​-100°C to +20°C dew-point

​8800T

​Aluminum Oxide (Al2O3)

​-100°C to +20°C dew-point


​8​800L​
​Tunable Diode Laser Spectroscopy (TDLAS)
​​0-5 ppm to 0-2,500 pp​m

Back to Top​



Nitrogen Analyzers ​ ​ ​

​Model Technology ​Range(s)
 ​
2120XL​​
​Plasma Ionization
​0-1, 0-10, 0-100 ppm user-settable, fixed or auto-ranging
Higher ranges optional

​Back to Top​


Nitrogen Oxides (NOx) & Ammonia Analyzers ​ ​ 

​​
​Model Gases​

​Technology

​Range(s)



​​

9110T​​Nitrogen Dioxide (NO2)​
​Nitric Oxide (NO)
Nitrogen Oxides (NOX)
Optional Oxygen (O2) with paramagnetic sensor
​Chemiluminescence​

​0-50 ppb (min)
0-20,000 ppb (max)
(selectable, independent Nitric Oxide (NO), Nitrogen Dioxide (NO2), Nitrogen Oxide (NOX) ranges and auto-ranging supported)
9110TH
​​Nitrogen Dioxide (NO2)​
​Nitric Oxide (NO)
Nitrogen Oxides (NOX)
Optional Oxygen (O2) with paramagnetic sensor
​Chemiluminescence

​0-5 ppm (min)
0-5,000 ppm (max)
(selectable, independent Nitric Oxide (NO), Nitrogen Dioxide (NO2), Nitrogen Oxide (NOX)​ ranges and auto-ranging supported)


913​0T​​

​Ammonia (NH3)
with optional NO/NO2/NOX​
​Chemiluminescence​
​​0-50 ppb (min)
0-20,000 ppb (max)
(selectable, independent Nitric Oxide (NO), Nitrogen Dioxide (NO2), Nitrogen Oxide (NOX) ranges and auto-ranging supported)

​Back to Top​​​


Oxygen Analyzers (Fixed)​ ​ ​
​​
Model Technology ​Range(s)
​​
​3000RS-M

​Paramagnetic
0-5% to 0-100%
3000RS-P

​Micro-Fuel Cell (Percent)
​0-1% to 0-100%
3000RS-T​
​Micro-Fuel Cell (PPM)
​0-10 ppm to 0-9,999 ppm
(0-1 ppm with -XL option)



3000MA​
​Paramagnetic

​0-5% to 0-100%
Calibration: 0-25%
3000PA​
​Micro-Fuel Cell (Percent)​
​0-1% (min), 0-100% (max)
Calibration: 0-25%
3000TA
Micro-Fuel Cell (PPM)
​0-10 ppm (min), 0-9,999 ppm (max)
Calibration: 0-25%
3000TA-XL​
​Micro-Fuel Cell (PPM)
​3 range customer selectable
(Minimum 0-1 ppm FS)
​​
3000MB​
​Paramagnetic
​​0-5% to 0-100%
Calibration: 0-25%
​3000PB​Micro-Fuel Cell (Percent)
​​0-1% (min), 0-100% (max)
Calibration: 0-25%
3000TB
​Micro-Fuel Cell (PPM)
​0-10 ppm (min), 0-9,999 ppm (max)
Calibration: 0-25%

​3000ZA2G​
​Zirconium Oxide (ZrO2)
​​0-10 ppm to 0-25%

​3010MA​​​Paramagnetic
90-100% O2
95-100% O2
98-100% O2
Other ranges available

3010PA​
​Micro-Fuel Cell (Percent)
​​​0-1% (min), 0-100% (max)
Calibration: 0-25%
3010TA​
​Micro-Fuel Cell (PPM)
​0-10 ppm (min), 0-9,999 ppm (max)
Calibration: 0-25%​
​​ ​3010PAC​
Micro-Fuel Cell (Percent)
Min: 0-1%
Max: 0-100%
3010TAC​
​Micro-Fuel Cell (PPM)
​0-10 ppm (min), 0-9,999 ppm (max)
Calibration: 0-25%

3010PB​
Micro-Fuel Cell (Percent)
​​0-1% (min), 0-100% (max)
Calibration: 0-25%
3010TB​
​Micro-Fuel Cell (PPM)
​​0-10 ppm (min), 0-9,999 ppm (max)
Calibration: 0-25%

3010PBC​
​Micro-Fuel Cell (Percent)​
​Min: 0-1%
Max: 0-100%
​3010TBC​
Micro-Fuel Cell (PPM)
​0-10 ppm (min), 0-9,999 ppm (max)
Calibration: 0-25%

3020M

Explosion Proof​ Paramagnetic
​0-5% to 0-100%
3020P​
​Explosion Proof Percent
​​0-1% (min), 0-100% (max)
Calibration: 0-25%

3020T​

Micro-Fuel Cell (PPM)
​0-10 ppm (min), 0-9,999 ppm (max)
Calibration: 0-25%

3190​
​Trace
​0-10 ppm to 0-9,999 ppm
Calibration: 0-25%
3290​​Percent
0-1% to 0-25% (optional 0-100%)



3300PA​
Micro-Fuel Cell (Percent)​
​0-1 to 0-25% oxygen
(0-3% and 0-10% default)
​3300TA​
Micro-Fuel Cell (PPM)
​Two ranges with auto ranging capability
Field configurable:
0-10ppm to 0-10,000ppm

​3300PB​
​Micro-Fuel Cell (Percent)
​​0-1 to 0-25% oxygen
(0-3% and 0-10% default)
3300TB​Micro-Fuel Cell (PPM)
​Two ranges with auto ranging capability
Field configurable:
0-10ppm to 0-10,000ppm​

3350​
​Micro-Fuel Cell 
​0-25% oxygen

9060Z​
​Zirconium Oxide (ZrO2)
​0.01 ppm to 100%

InstaTrans-XD​​Micro-fuel Cell (Percent or ppm)
​0-10 ppm to 0-25%​


OT-3​
​Micro-fuel Cell (ppm)
​0-10 ppm
0-9,999 ppm 
Calibration: 0-25%

UltraTrace-3000​​Micro-fuel Cell (ppm)
Default: 0-250ppb, 0-1ppm
0-10 ppm
Fixed Over: 0-1,000 ppm


Oxygen Analyzers (Portable)​ ​ ​
​​
Model Technology ​Range(s)
​​
​3110​
Micro-fuel Cell (​Trace / Percent)
​0-10 ppm to 0-25%

​3110P​
Micro-fuel Cell (Percent)
​0-1% to 0-25%*
(optional 0-100%*)

*third-party approval apply only for process streams up to 20.9%
3110XL​
Micro-fuel Cell (​Trace / Percent)
​​0-2 ppm to 0-25%



GB-300​Micro-fuel Cell (​Percent)
​0-100% Oxygen (O2)

PEM-9004

​Micro-fuel Cell​

​0-25% vol O2
0-4,000 ppm vol CO
0-2,000 ppm vol ​NO
0-2,000 ppm vol SO2



Sulfur Analyzers ​ ​ ​

​Model ​Gases  Technology ​Range(s)
​​

6020L​Hydrogen Sulfide (​H2S)
​Tunable Diode Laser Spectroscopy (TDLAS)
​0-10 ppm to 0-20%

6200T​
Total Sulfur

​​UV-Fluorescence
​0-50 ppb (min)
0-20,000 ppb (max)



6400T
Sulfur Dioxide (SO2​)

​UV-Fluorescence
0-50 ppb (min)
0-20,000 ppb (max)​
6400T-H2S​

​Hydrogen Sulfide (H2S)
​UV- Fluorescence
​0-50 ppb (min)
0-10,000 ppb (max)
6400TH​
Sulfur Dioxide (SO2​)
​UV-Fluorescence
​0-10 ppm (min)
0-5,000 ppm (max)

6400TSG Total Sulfur ​UV-Fluorescence
PPB to percent levels,
application specific

​Back to Top​


Thermal Conductivity Analyzers ​ ​ ​

​Model Technology ​Range(s)

2000A​​Thermal Conductivity
​Per application

2000B​​Thermal Conductivity
Per application

2000XTC​​Thermal Conductivity
Per application

​2010A​​Thermal Conductivity
Per application

​2010B​​Thermal Conductivity
Per application

​2020​​Thermal Conductivity
Per applica​tion
 
2750​
​​Thermal Conductivity​
0-100% H2 in CO2
0-100% Air in CO2
80-100% H2 in Air 



​Back to Top



Tunable Diode Laser (TDL) Analyzers ​ ​ ​

​Model Gases Technology ​Range(s)
​​
6020L
Carbon Dioxide (CO2)
Hydrogen Sulfide (H2S)
​Tunable Diode Laser Spectroscopy (TDLAS)
0-100 ppm to 0-100%​​
​​0-10 ppm to 0-20%
8800L​​Moisture (H2Ov)
​Tunable Diode Laser Spectroscopy (TDLAS)
​​​0-5 ppm to 0-2,500 pp​m




LGA-4000Z​Acetylene (​C2H2)
Ammonia (NH3)
Carbon Dioxide (CO2)
Carbon Monoxide (CO)
Ethylene (C2H4​)
Hydrogen Chloride (HCl)
Hydrofluoric Acid (HF)
Hydrogen Sulfide (H2S)
Methane (CH4)
Oxygen (O2)
Water (H2O)
​Tunable Diode Laser Spectroscopy (TDLAS)

​0-50 ppm to 0-100%
0-10 ppm to 0-100%
0-1,000 ppm to 0-100%
0-1,000 ppm to 0-100%
0-100 ppm to 0-100%
0-100 ppm to 0-50%
0-20 ppm to 0-50%
0-100 ppm to 0-100%
0-200 ppm to 0-100%
0-1% to 0-25%
0-100 ppm to 0-100%


Ultraviolet Analyzers ​ ​ ​
​Model Gases Technology ​Range(s)
​​
6000B
​Contact Factory
​​UV Light Absorption
​Three user selectable ranges
6020​
​Contact Factory
​​UV Light Absorption​​
​Three user selectable ranges

6020L​
Carbon Dioxide (CO2)
Hydrogen Sulfide (​H2S)

​Tunable Diode Laser Spectroscopy (TDLAS)
0-100 ppm to 0-100%
​​0-10 ppm to 0-20%


6020UV
​Contact Factory
​UV Light Absorption
​PPM to Percent
Application Dependent

6200T​Total Sulfur

​UV-Fluorescence
​​0-50 ppb (min)
0-20,000 ppb (max)

​​
​6400T​Sulfur Dioxide (SO2​)

​​UV-Fluorescence
​0-50 ppb (min)
0-20,000 ppb (max)​
6400T-H2S​
​Hydrogen Sulfide (H2S)
​UV-Fluorescence
​0-50 ppb (min)
0-10,000 ppb (max)

6400TH​

Sulfur Dioxide (SO2)​
​UV-Fluorescence​
​0-10 ppm (min)
0-5,000 ppm (max)

​​​Back to Top


​​