Model | Technology
|
Gases |
Range(s) |

|
5000B
| Near Infrared (NIR) Absorption
| Contact Factory
| Three user selectable ranges
|
| 5020
| Near Infrared (NIR) Absorption
| Contact Factory
| Three user selectable ranges
|

|
5020IR | Near Infrared (NIR) Absorption
| Contact Factory
| ppm to Percent Application-Dependent
|
|
6020L
| Tunable Diode Laser Spectroscopy (TDLAS)
| Carbon Dioxide (CO2) Hydrogen Sulfide (H2S)
| 0-100 ppm to 0-100% 0-10 ppm to 0-20%
|
| 7300A
| Non-Dispersive Infrared (NDIR)
| Carbon Dioxide (CO2) Carbon Monoxide (CO) Methane (CH4) C2 to C5
| 0-1% to 0-100% 0-5% to 0-100% 0-10% to 0-100% 0-5% to 0-100%
|
7300B
| Non-Dispersive Infrared (NDIR)
| Carbon Dioxide (CO2) Carbon Monoxide (CO) Methane (CH4) C2 to C5
| 0-1% to 0-100% 0-5% to 0-100% 0-10% to 0-100% 0-5% to 0-100%
|

| 7320
| Non-Dispersive Infrared (NDIR)
|
Carbon Dioxide (CO2) Carbon Monoxide (CO)
Methane (CH4) C2 to C5
| 0-1% to 0-100% 0-5% to 0-100% 0-10% to 0-100% 0-5% to 0-100%
|

|
7500ZA / 7500ZB | Non-Dispersive Infrared (NDIR)
| Carbon Dioxide(CO2) Carbon Monoxide (CO) Methane (CH4) Nitric Oxide (NO) Oxygen (O2) (fuel cell) Oxygen (O2) (paramagnetic) Sulfur Dioxide (SO2)
|
0-100 ppm to 0-100% 0-200 ppm to 0-100% 0-500 ppm to 0-100% 0-200 ppm to 0-5,000 ppm 0-10% to 0-25% 0-5% to 0-100% (7500ZA) 0-200 ppm to 0-10%
|
7600ZA / 7600ZB | Non-Dispersive Infrared (NDIR)
| Carbon Dioxide(CO2) Carbon Monoxide (CO) Nitric Oxide (NO) Oxygen (O2) (fuel cell) Oxygen (O2) (paramagnetic) Sulfur Dioxide (SO2)
| 0-50 ppm to 0-25% 0-50 ppm to 0-5,000 ppm 0-50 ppm to 0-5,000 ppm 0-10% to 0-25% 0-5% to 0-100% 0-50 ppm to 0-5,000 ppm
|
7600ZAXL
| Non-Dispersive Infrared (NDIR)
| Carbon Dioxide(CO2) Carbon Monoxide (CO) Nitric Oxide (NO) Oxygen (O2) (fuel cell) Oxygen (O2) (paramagnetic) Sulfur Dioxide (SO2)
| 0-5 ppm to 0-50 ppm 0-5 ppm to 0-50 ppm 0-10 ppm to 0-100 ppm 0-10% to 0-25% 0-5% to 0-100% 0-10 ppm to 0-100 ppm
|

| 8800L
| Tunable Diode Laser Spectroscopy (TDLAS)
| Moisture (H2Ov)
| 0-5 ppm to 0-2,500 ppm
|

|
GFC-7000T | Infrared Absorption with Gas Filter Correlation
| Carbon Dioxide (CO2)
| 0-2 ppm to 0-2,000 ppm
(0-100 ppb to 0-100 ppm for -U version) (dual ranges and auto ranging supported)
|
GFC-7001T | Infrared Absorption with Gas Filter Correlation
| Carbon Monoxide (CO)
| 0-1 ppm to 0-1,000 ppm (0-100ppb to 0-100ppm for-U version) (dual ranges and auto ranging supported)
|
GFC-7002T | Infrared Absorption with Gas Filter Correlation
| Nitrous Oxide (N2O)
| 0-1 ppm to 0-1,000 ppm
(0-200 ppb to 0-200 ppm for -U version) (dual ranges and auto ranging supported)
|