Model 5650

Water Cut Meter​​​​​



 Description

The Model 5650 Water Cut Monitor is designed to produce superior results in operating environments from the North Sea to the Sahara Desert. Delivering unmatched flexibility in material, size, features and configurations, the 5650 can be integrated into almost any oil carrying system. Applications include monitoring pipeline transfers, enhancing dehydration equipment efficiencies by monitoring water content before and​ after desalinization, early detection of undesirable conditions in petroleum storage facilities and detecting and rerouting oil with excess water content.


Reliability and Flexibility

The Model 5650 is designed with reliability and flexibility in mind. Incorporating decades of experience with capacitance probe engineering, the 5650 is one of the most reliable water cut monitors on the market. Built-in logic compensates for vast temperature effects in the dielectric constant of the water while remaining sensitive to the much smaller dielectric constant effects of oil. ​​

The 5650 is also built to the strictest standards with the ability to accommodate many different piping specifications. Dedication to precision allows the 5650 to become an integral part of the piping system rather than the weakest link in the chain, like many other external monitoring systems.


High Accuracy

Proper stream flow conditioning is the key to high accuracy water cut metering. The Model 5650 can be supplied with a built-in static mixer to provide a well conditioned stream for highly accurate readings for both in-line measurement and sampling, reaching unparalleled accuracy over many ranges of water content.​



 Features

  • Reliable capacitance detection technology

  • Sizes from 1 to 48 inches, ranges 0-25% or 0-100%

  • Intrinsically safe and explosion-proof configurations

  • Direct in-situ or bypass configurations

  • Integral temperature compensation

 Specifications

​Respo​nse Time

​< 1 second

​Sensitivity

​0.01%

​Accuracy

​Up to 5% water cut:        ± 0.05%
5% to 10% water cut:      ± 0.1%
10% to 25% water cut:    ± 0.2%

​Repeatability

​0.1%

​Output

​4-20 mA with HART protocol

​Power

​Supply:                 24 VDC (Loop Powered)
Consumption:     0.66 W

​Temperature

​Media:        300°F (150°C)
Ambient:    140°F (60°C)

​Ingress Protection

​IP66

​Range

​0-25% or 0-100%

​Flange Rating

​Up to 1500#

​Sizes

​From 1" to 48"

​Material

​316L Stainless Steel
(for standard sizes 1" to 4")

​Options

​EEx d, sample ports, built-in mixer

​​Protection

​Intrinsically safe
Ex ia IIB T4 (-20°C to 60°C) (IECEx​, ATEX, US/CAN)
IP-66 316LSS
Optional dual chamber with explosion-proof housing


 Applications

  • Pipelines

  • Dehydration Equipment

  • Storage and Treating Facilities

  • Lease Automatic Custody Transfer (LACT) Units​

 Downloads

Title

​File Size​

Model 5650 Brochure

1.53MB​

Model 5650 Declaration of Conformity​

​​281KB

​​