APPLICATIONS
|
INDUSTRY
(FACILITY)
|
SERVICE
|
PARAMETER
|
RANGE
|
BACKGROUND
|
TELEDYNE MODEL
|
|
Tour our in-depth review of how Teledyne's systems address the measurement
of oxygen in natural gas extracted from coal bed methane deposits.
|
LNG Production
Mobil
|
Overhead / top outlet
|
Percent H2
|
0-3, 0-6%
|
N2 / CO2, ppm H2S
|
2020 TCD
|
|
Process gas
|
PPM CO2
|
0-10 ppm
|
Air
|
7500
|
|
Outlet to N2 header / purity
|
PPM O2
|
0-10 ppm
|
N2
|
3000T
|
|
Top inlet / safeguard monitor
|
PPM Hydrocarbons
|
0-2 ppm
|
Air
|
402REU
|
|
PPM HC in water
|
0-10 ppm
|
HC in condensate
|
402REU + 1100A stripper
|
|
Wet gas flare header
|
PPM O2
|
0-2000 ppm
|
C3 Hydrocarbons
|
3020P
|
|
Thermal incinerator stack
|
Percent O2 PPM SO2
|
15% O2, 250 ppm SO2
|
N2, CO, SO2, CO2
|
9060 ZrO2 / 6000 (SO2)
|
| |
LNG Transmission
LNG Gathering Systems
|
Dry gas production lines
|
PPM O2
|
0-10 ppm
|
LNG
|
311 (spot check for leaks)
|
|
Field compressor section
|
0-100 ppm
|
OT-3 (prevent explosions)
|
|
Gas treatment facility
|
3020T (unmonitored collection)
|
|
Main receiving station
|
3020T (verifies gas treatment)
|
|
Liquid extraction facility
|
3020T (catalyst protection)
|
|
NOTE: PPM CO2 analyzers (IR-7000) can be applied at the same
points as noted above for corrosion prevention purposes and to minimize carbonic acid formation.
|
| |
|
Landfill gas power station
|
Landfill gas feed to incinerator boiler
|
Percent O2 & CH4
|
0-5% O2 0-50% CH4
|
CH4, CO2, O2
|
3020P / 7320 NDIR
|
|
OFF SHORE OIL PRODUCTION
|
Read Teledyne's informative application bulletin
UV versus IR Monitoring for PPM Oil-in-Water - PDF
|
INDUSTRY
(FACILITY)
|
SERVICE
|
PARAMETER
|
RANGE
|
BACKGROUND
|
TELEDYNE MODEL
|
|
Off-shore drilling platform
|
Produced water
|
Oil
|
0-100 ppm
|
Water
|
Series 6600 UV
|
|
Rig wash
|
Water / Rain run
|