Turbine Generator Hydrogen Purity Problem Hydrogen in air is a potentially explosive mixture. Monitoring hydrogen purity prevents the danger of an explosion due to air leaks. During routine purging of hydrogen-cooled turbine generators, monitoring of hydrogen in CO2, or CO2 in air, prevents premature entry into the generator. Measurement Hydrogen purity - 80 to 100% H2 in air Hydrogen in CO2 - 0 to 100% H2 in CO2 CO2 in air - 0 to 100%CO2 in air Teledyne Solution Model 2000 Series of microprocessor based thermal conductivity analyzers Model 275R Portable Turbine Generator Analyzer Power Generation | Cement | Refining | Food and Beverage | Pharmaceutical Steel | Pulp and Paper | Semiconductor | Various |
|||||
|
Document Control & Training (password) e-mail us: ask_tai@teledyne.com Copyright © 2007 Teledyne Technologies Incorporated. All rights reserved. Teledyne Analytical Instruments 16830 Chestnut St City of Industry, CA 91748 USA |