| MODEL |
ANALYZER TYPE |
RANGES |
1220 & 1220-3
|
Multi-point combustibles analysis system for ambient detection of volatile hydrocarbons |
0-100% LEL |
|
| MODEL |
ANALYZER TYPE |
RANGES |
2000A
|
General purpose - wall or flush panel mount (typically for H2, Ar or N2) |
Application dependent |
2000XTC
|
Wall mount transmitter (configured to detect H2, He, N2, Ar, CO2 or a
number of other gases in binary or multi-component sample gas mixtures) |
Customer specified |
2010
|
Semi-explosion proof - wall or flush panel mount control unit (typically for H2 analysis) |
Application dependent |
2020
|
Fully-explosion proof, wall mount, (typically for H2 in hydrocarbon analysis) |
Application dependent |
212R
|
Flush panel mount, trace thermal conductivity analyzer (typically for H2, Ar or N2) |
Application dependent; standard with triple range capability |
225CM
|
Nuclear hydrogen / oxygen monitoring |
Contact factory |
2750
|
Portable percent TCD analyzer, designed for turbine generator applications (H2 in Air) |
0-100% H2 in CO2
0-100% Air in CO2
80 - 100% H2 in Air |
| MODEL |
ANALYZER TYPE |
RANGES |
2120
|
Nitrogen in Argon analyzer |
Model dependent, see data sheet |
| MODEL |
ANALYZER TYPE |
RANGES |
402REU
|
PPM trace total hydrocarbons FID, 19" relay rack, general purpose, Div 1 or Div 2 via purge - gas phase |
0-1 to 0-5000 ppm |
4020
|
Microprocessor based total trace hydrocarbon analyzer |
0-10, 0-100, 0-1000 ppm HC standard
(CH4 equivalent, lower optional ranges available) |
4030
|
Total hydrocarbon gas analyzer heated for emissions |
0-10, 0-100, 0-1000 ppm THC. Other ranges available. |
4040
|
Methane / Nonmethane Analyzer |
0-10, 0-100, 0-1000 ppm |
4060
|
Benzene analyzer |
0-100 ppb, 0-1 ppm, 0-10 ppm benzene |
4080
|
Hydrocarbon in water analyzer |
|
| MODEL |
ANALYZER TYPE |
RANGES |
8800 Series
|
Trace moisture analysis instrumentation |
-100 to 20C or -65 to 20C based on sensor |
| MODEL |
ANALYZER TYPE |
RANGES |
LXT Series
|
On line analysis of pH, ORP, PION, DO Conductivity & Resistivity |
Application specific |
6700 TOC Series
|
Total Organic Carbon analyzers |
Analysis method specific |
| MODEL |
ANALYZER TYPE |
RANGES |
LGA-3500 Series
|
Tunable Diode Laser Absorption Spectroscopy (TDLAS) applied to O2, CO, CO2, CH4, NH3, HCL, and H2Ov analysis |
Application / parameter dependent |
| MODEL |
ANALYZER TYPE |
RANGES |
AN300
|
Hand held, portable, nitrogen analyzer |
0-100 % nitrogen (100% O2%) |
Transcrub
|
Transparent scrubber for H2S |
N/A |
|
|
|