Teledyne’s Model 402REU Hydrocarbon Analyzer utilizes a flame ionization detector for the continuous measurement of total hydrocarbons at trace levels in process gas streams. The principle of operation is based on measuring the ion current generated when organic compounds are dissociated in a hydrogen flame. Full scale monitoring as low as 0-1 ppm is available. The 402REU is ideal for monitoring hydrocarbon contamination in high purity gases (nitrogen, argon, oxygen, hydrogen) and for other industrial applications. This unit features a compact 19" rack mountable housing, digital readout, signal output and an optional sample selector module that controls sample, zero and span gases. Detector The heart of the 402REU is a flame ionization detector (FID). Sample gas entering the detector is heated in a hydrogen flame, which ionizes the hydrocarbons. The ionized hydrocarbons cause a current to flow between two electrodes in the flame. This current is proportional to the level of hydrocarbons present and is measured by a precision electrometer amplifier. The signal generated is sent to the analyzer electronics for processing. Gas Control System The 402REU controls gas flow and assures accuracy by maintaining a pressure drop across unique sintered stainless steel restrictors. A pressure regulator maintains constant flow over a wide range of sample inlet pressures. Sample and auxiliary gas flow hardware are contained in a temperature controlled chamber for optimum stability throughout the operating temperature range. The low volume sample path, in conjunction with a variable sample bypass system, provides fast response to process changes. Electronic Flame Guard A flame guard circuit is a standard feature on the 402REU. This circuit uses a thermistor to monitor flame condition; an indicator light confirms routine flame operation. In the event of a flame out or power failure, the flame guard circuit activates an alarm and closes the fuel shut-off solenoid valve, thereby preventing any fuel leaks. Optional Sample Selector Module This recommended option provides an easy access integral system for control of sample, span and zero gases. Included with this option are a manual 3-way valve, sample bypass flowmeter, and all necessary tubing and fittings. The system is integral and fully assembled. The front panel of the unit is hinged allowing easy access to the sample selector module and gas control system. The case also features a removable top panel for easy maintenance. Features
|
|||||||
|
Document Control & Training (password) e-mail us: ask_tai@teledyne.com Copyright © 2007 Teledyne Technologies Incorporated. All rights reserved. Teledyne Analytical Instruments 16830 Chestnut St City of Industry, CA 91748 USA |