AX-300 Medical Oxygen Analyzer & MX-300 Medical Oxygen Monitor
Explain the error codes for the MX300. Top of page What is the format of the RS-232 messaging from the MX300? The MX300 broadcasts RS-232 concentration data with resolution of 0.1% O2 approximately once per second. The baud rate is 2400; there are 7 data bits with odd parity. Top of page Concerning the installation of the MX-300, there is a blue "T" in the box. One end goes to the air supply, one end to the sensor. Is the third end open to the atmosphere? Yes, this is the T-flow through adapter. The sensor should be vented at atmospheric pressure. Top of page Is the T adapter reusable? The adapter is not reusable. It is a disposable T adapter made of high density polyethylene. Top of page The blue T-adapter diffuser has a spiderweb obstruction in the tube. The old ones did not have this construction. Can you please tell us why? Teledyne has sold different types of T-adapters in the past. The current blue T-adapter is multipurpose, and the spider-web inside does not effect its use. Top of page Can you tell us the response time of this monitor and/or sensor? Does it take longer to change its displayed reading with a high or low flow of gas? The response time is determined by the sensor. See the specifications sheet. And yes, an insufficient gas flow will cause a slower response. Top of page What is the maximum flow rate for the MX300 / AX300? When used with the provided T adapter, we have not been able to identify a maximum limit. We have run the device at up 80 scfh and found no change in concentration due to flow rate. Top of page What is the update rate for these units? About once per second. Top of page Can you please tell me if the blue T adapter can be autoclaved and if so to what temperature? The Blue T adapter is not intended for Autoclaving. We do offer an optional version of the T adapter that is autoclave suitable. (part number A274). Your local representative who supplied the units to you should be able to also supply you with the optional T adapter. Top of page Do you know how long the unit might continue to operate when the low battery indicator shows no bars left? We have no specific data on this condition, but from our limited data we can hypothesize the unit could go for 4 to 5 days in a non-alarm condition. Top of page Do you still sell the universal mounting clamps for the AX300/MX300? Yes, the universal mounting clamp for the AX300/MX300 is part number CP2345. Top of page |
||||||||||||||||||||||||||||||||||||||
|
Document Control & Training (password) e-mail us: ask_tai@teledyne.com Copyright © 2007 Teledyne Technologies Incorporated. All rights reserved. Teledyne Analytical Instruments 16830 Chestnut St City of Industry, CA 91748 USA |