Model 4030

Total Hydrocarbon Analyzer

 

 Description

The Model 4030 uses a field proven FID detector in a heated chamber. The chamber is heated to a high temperature to meet US EPA requirements for VOC emissions monitoring.


4000 Series Overview:

All 4000 series units employ the same basic architecture and electronics; however, each analyzer has additional features:

​4020 Total Hydrocarbon Analyzer

​Uses FID to measure total hydrocarbons in ppm in a sample gas stream

​4030 Total Hydrocarbon Analyzer

​Basic 40​​20 with sample system at a higher temperature for heated applications

Avoids condensation of the sample

​4040 Methane / Non-Methane

​Basic 4020, plus temperature-controlled sampling system with GC column to give accurate readings of both methane and non-methane hydrocarbons in a gas stream

4060 Benzene Analyzer

​Same as 4040, but used to measure ppb levels of benzene instead of methane/non-methane

4080 Total Hydrocarbon Analyzer

​Basic 4020 with sample system including stripper to measure total hydrocarbons in an aqueous sample


 Features

  • ​Easy to use software, user programmable ranges

  • GC technology used for complete separation of Methane, Ethylene Oxide, Benzene, Styrene, BTX and many other compounds (application dependent)

  • Automatic fuel shut off system

  • Electronic flame-out guard circuit

  • Adjustable alarm and oven settings

  • Fast response

  • Sample filter with exchangeable stainless steel element

  • Built-in sample pump (optional)

  • Stainless steel sample system with flexible design to handle either a 100% H2, H2/N2 or H2/He support gas fuel mixture

  • Automatic ignition

  • X-purged configuration for hazardous area installations available

  • Standard auto-calibration programming, ideal for unmanned plant conditions

  • Enhanced temperature control of sample compartment for stable, reproducible results

  • Easily accessible pressure and flow control devices

  • Slide out chassis design for easy access to internal components

  • CE marked

  • Optional methanizer for CO and CO2 measurements


 Specifications

​Ranges​​

​0-10, 0-100, 0-1000 ppm THC. Other ranges available

Sensitivity

1% of FS

Resolution

​0.1 ppm

​Accuracy

​± 2% of FS at constant temperature

Response Time

​90% in less than 15 seconds, data updated every 5 minutes

​Temperature

​40° to 110° (4.44° to 43.33°C)

​Fuel

​UHP Hydrogen @ 30 PSI incoming pressure (standard)

​Power

​115 or 220 VAC, 50/60Hz, 600VA

​Noise

​Less than 0.5% of FS

​Drift

​2% FS per week

​Linearity

​1% FS through all ranges

​Repeatability

​​1% FS through all ranges

​Sample Chamber

212° to 248°F (100° to 120°C) per application

​Flow Rate

​1 Liter/minute (standard)

​Outputs

​0-1 VDC & 4-20 mADC, isolated current output

​Warm-Up Time

​Usable in approximately 4 hours
Stable in approximately 8 hours

​Carrier Gas

​UHP Nitrogen @ 50 PSI incoming pressure

​​Enclosure

​19" rack mounted steel enclosure
19"W x 8.75"H x 15.5"D
(48.3 x 22.2 x 39.4 cm)



 Applications

  • Ambient monitoring of THC

  • THC​​ measurement of automotive exhaust

 Downloads

Title

​File ​​Size​

Model 4030 Brochure

​3.72MB

Model 4030 M​anual

1.03MB

​Model 4030 Declaration of Conformity​