Model InstaTrans-XD​​​

Oxygen Transmitter​​​​​​



Description

Design

This model utilizes a design to meet the requirements of NEMA-4(IP-66) levels as well as ATEX Zone 0/1/2 and FM/FMc Class I Div 1 approvals when used with select intrinsic safety barriers. In addition, the CSA approval extends to Class I Div 2 as a non-incentive device without the use of barriers. The transmitter head contains the electronics and user display interface including 4-button design to access functions.


Platform

A fully upgraded microprocessor-based platfor​m gives a more compact, single PCB design to simplify maintenance and reduce shelf spares. The new interface allows for a fully settable single range form 0-10 ppm to 0-25%. New advanced functions are also available as standard including 4-20mA output adjustment to optimize single output and cold boot capability as a beneficial troubleshooting tool.


Additional Advantages

  • ​2-wire transmitter form factor

  • InstaTrace capability for fast recovery from new sensor installation (optional) Accepts most industrial micro-fuel cells

  • Trace or percent oxygen analysis - settable ranging from 0-10 ppm to 0-25%

  • Intrinsically safe design for hazardous are non-hazardous installations


Fittings (all 316SS)

  • ​Standard - 1/8" tube

  • 1/4" tube

  • 6mm tube

  • No fitting - 1/8" FNPT thread

InstaTrace for Fast Initial Recovery

  • Non InstaTrace

  • InstaTrace


O-ring Seals

  • ​Standard Viton®

  • Buna-n

  • Kalrez®

  • EPDM

  • EPR

  • Neoprene

  • Chemraz®




Features

  • Single user-settable range, 0-10 ppm to 0-25% Oxygen

  • Front-facing head containing digital display and keys for convenient wall mounting

  • Accepts most Teledyne industrial sensors (InstaTrace and A-5 type cells require special configurations)

  • Weather-tight housing designed to meet NEMA-4 / IP-66 ingress protection requirements

  • 316SS cell housing with 316SS 1/8" tube fittings and Viton® O-ring​ as standard

  • Optional fittings: 1/4" tube, 6mm tube, no fitting (1/8" FNPT threads)

  • Optional O-rings of Kalrez®, EPDM, EPR, Neoprene, Chemraz® and Buna-n

  • Microprocessor-based single PCB design

  • 4.5 digit LCD

  • 4-20mA loop output

  • Cold boot and 4-20 fine adjust features included as standard

  • Intrinsically safe to ATEX Ex ia IIC T4 Ga when wired with approved barrier as per D86181 Interconnection Diagram

  • Intrinsically safe to FM / FMc Class I Div 1 Gp A-D T4 when wired with approved barrier as per Interconnection Diagram and FM / FMc Class I Div 2 Gp A-D T4 without barrier (approvals pending)

  • Cable included, 2-conductor 22 AWG shielded, 24 inch (610 mm) length

  • Fuel cell included​


Specifications

​Range

​Single-range, user-settable, 0-10 ppm to 0-25%

​Micro-Fuel Cells

​Trace O2 general service:               Class B-2C
Trace O2 % CO2 present:               Class A-2C
InstaTrace, general service:           B71875 InstaTrace
InstaTrace, % CO2 present:           B73016 InstaTrace
Percent O2, general service:          Class B-1/B-1C
Percent O2, % CO2 present:          Class A-5/A-5C (special configuration)

​Temperature

​32° to 122°F (0° to 50°C)

​Accuracy

​± 1% of FS operating range
(± 1 ppm below 0-100 ppm range)

​Response Time

​15 seconds
(40 seconds below 0-100 ppm range)

​Flow Rate

​1-2 SCFH (0.5-1 SLPM)

​Display

​4.5 digit LCD

​Power

​9-24 VDC, loop-powered

​Output

​Loop 4-20 mADC​

​Weight

​​Approximately 6 lbs


​​