​​Gas Analyzers​

​> Carbon Dioxide Systems​​​
Infrared
Nitrogen Oxides / Ammonia
> Sulfur
> Ultraviolet​

> Gas Chromatographs
> Moisture
> Oxygen (Fixed)
Thermal Conductivity

> Hydrocarbon
> Nitrogen
> Oxygen (Portable​)
> Tunable Diode Laser



Carbon Dioxide Systems​

​​​​
​Model Description ​Gases




CDQC

Carbon Dioxide Quality Control System

Carbon Dioxide (CO2) Purity
Acetaldehyde (C2H4O)
Ammonia (NH3)
Aromatic Hydrocarbon
Benzene (C6H6)
Carbon Monoxide (CO)
Methanol (CH3OH)
Moisture (H2Ov)
Nitric Oxide (NO)
Nitrogen Dioxide (NO2)
Oxygen (O2)
Sulfur Dioxide (SO2)
Total Sulfur
Total Volatile Hydrocarbons

Gas Chromat​​ographs​

​​​​
​Model Description ​Detectors



Falcon GC​

Ultra-Fast Gas Chromatograph for Process and Lab Applications

• Aspiration to inlet via sample pump​
​• Process online via sample valve for         gas or liquid*
• Autosampler injections for liquid or       heated headspace
• Manual sy​ringe injection for gas or          liquid​

*Sample handling available

Dielectric Barrier Discharge (DBD)
​Flame Ionization (FID)
Flame Photometric (FPD)
Thermal Conductivity (TCD)


​4000 Series​​

Ultra-Fast Rack-Mount Gas Chromatograph

• Process online via sample valve for         gas and aspiration

Dielectric Barrier Discharge (DBD)
Flame Ionization (FID)
Flame Photometric (FPD)
Thermal Conductivity (TCD)​


4040

Methane / Non-Methane Gas Chromatograph

​Flame Ionization (FID)

4060​

Gas Chromatograph

​Flame Ionization (FID)
Plasma Emission Detector (PED)​
Thermal Conductivity (TCD)

​​Back to Top​​​​


 ​​Hydrocarbon Analyzers ​ ​ ​
​Model ​Configuration ​Range(s)


4020​Total Hydrocarbon ​ Analyzer
​0-10, 0-100, 0-1,000 ppm THC standard
Other ranges including down to 0-1ppm available
​4030​Total Hydrocarbon Analyzer
semi-continuous for heated or ambient samples
​​0-10, 0-100, 0-1,000 ppm THC standard
Other ranges including down to 0-1ppm available


Infrared Analyzers ​ ​ ​

​ModelTechnology
​Gases ​Range(s)​​








​7500ZA​Non-Dispersive
Infrared (NDIR)
Carbon Dioxide(CO2)
Carbon Monoxide (CO)
Methane (CH4)
Nitric Oxide (NO)
Oxygen (O2) (fuel cell)
Oxygen (O2​) ​(paramagnetic)
Sulfur Dioxide (SO2)
0-100 ppm to 0-100%
0-200 ppm to 0-100%
0-500 ppm to 0-100%
​0-200 ppm to 0-5,000 ppm
0-10% to 0-25%
0-5% to 0-100% (7500ZA)
​0-200 ppm to 0-10%
​7600ZA​Non-Dispersive Infrared (NDIR)
Carbon Dioxide(CO2)
Carbon Monoxide (CO)
Nitric Oxide (NO)
Oxygen (O2) (fuel cell)
Oxygen (O2​) ​(paramagnetic)
Sulfur Dioxide (SO2)
0-50 ppm to 0-25%
0-50 ppm to 0-5,000 ppm
​0-50 ppm to 0-5,000 ppm
0-10% to 0-25%
0-5% to 0-100%

0-50 ppm to 0-5,000 ppm








​​
​GFC-7000T​​Infrared Absorption with Gas Filter Correlation
Carbon Dioxide (​CO2)
​0-2 ppm to 0-2,000 ppm 
(0-100 ppb to 0-100 ppm for -U version)
(dual ranges and auto ranging supported)
​GFC-7001TInfrared Absorption with Gas Filter Correlation
Carbon Monoxide (​CO)
​0-1 ppm to 0-1,000 ppm 
(0-100ppb to 0-100ppm ​for-U version)
(dual ranges and auto ranging supported)
GFC-7002T​Infrared Absorption with Gas Filter Correlation
​Nitrous Oxide (N2O)
​0-1 ppm to 0-1,000 ppm
(0-200 ppb to 0-200 ppm​ for -U version)
(dual ranges and auto ranging supported)


Moisture Analyzers ​ ​ 

​Model Technology ​Range(s)

8800A​
​Aluminum Oxide (Al2O3)
​-100°C to +20°C dew-point

8800B
​Aluminum Oxide (Al2O3)
​-100°C to +20°C dew-point

​8800P​

​Aluminum Oxide (Al2O3)
​-100°C to +20°C dew-point

​8800T

​Aluminum Oxide (Al2O3)

​-100°C to +20°C dew-point

Back to Top​



Nitrogen Analyzers ​ ​ ​

​Model Technology ​Range(s)
 ​
2120XL​​
​Plasma Ionization
​0-1, 0-10, 0-100 ppm user-settable, fixed or auto-ranging
Higher ranges optional

​Back to Top​


Nitrogen Oxides (NOx) & Ammonia Analyzers ​ ​ 

​​
​Model Gases​

​Technology

​Range(s)



​​

9110T​​Nitrogen Dioxide (NO2)​
​Nitric Oxide (NO)
Nitrogen Oxides (NOX)
Optional Oxygen (O2) with paramagnetic sensor
​Chemiluminescence​

​0-50 ppb (min)
0-20,000 ppb (max)
(selectable, independent Nitric Oxide (NO), Nitrogen Dioxide (NO2), Nitrogen Oxide (NOX) ranges and auto-ranging supported)
9110TH
​​Nitrogen Dioxide (NO2)​
​Nitric Oxide (NO)
Nitrogen Oxides (NOX)
Optional Oxygen (O2) with paramagnetic sensor
​Chemiluminescence

​0-5 ppm (min)
0-5,000 ppm (max)
(selectable, independent Nitric Oxide (NO), Nitrogen Dioxide (NO2), Nitrogen Oxide (NOX)​ ranges and auto-ranging supported)

​Back to Top​​​


Oxygen Analyzers (Fixed)​ ​ ​

​​
Model Technology ​Range(s)



3000MA​
​Paramagnetic

​0-5% to 0-100%
Calibration: 0-25%
3000PA​
​Micro-Fuel Cell (Percent)​
​0-1% (min), 0-100% (max)
Calibration: 0-25%
3000TA
Micro-Fuel Cell (PPM)
​0-10 ppm (min), 0-9,999 ppm (max)
Calibration: 0-25%
3000TA-XL​
​Micro-Fuel Cell (PPM)
​3 range customer selectable
(Minimum 0-1 ppm FS)
​​
3000MB​
​Paramagnetic
​​0-5% to 0-100%
Calibration: 0-25%
​3000PB​Micro-Fuel Cell (Percent)
​​0-1% (min), 0-100% (max)
Calibration: 0-25%
3000TB
​Micro-Fuel Cell (PPM)
​0-10 ppm (min), 0-9,999 ppm (max)
Calibration: 0-25%

​3010MA​​​​Paramagnetic
90-100% O2
95-100% O2
98-100% O2
Other ranges available
​​ ​3010PAC​
Micro-Fuel Cell (Percent)
Min: 0-1%
Max: 0-100%
3010TAC​
​Micro-Fuel Cell (PPM)
​0-10 ppm (min), 0-9,999 ppm (max)
Calibration: 0-25%

3010PBC​
​Micro-Fuel Cell (Percent)​
​Min: 0-1%
Max: 0-100%
​3010TBC​
Micro-Fuel Cell (PPM)
​0-10 ppm (min), 0-9,999 ppm (max)
Calibration: 0-25%

3020M

Explosion Proof​ Paramagnetic
​0-5% to 0-100%
3020P​
​Explosion Proof Percent
​​0-1% (min), 0-100% (max)
Calibration: 0-25%

3020T​

Micro-Fuel Cell (PPM)
​0-10 ppm (min), 0-9,999 ppm (max)
Calibration: 0-25%

3190​
​Trace
​0-10 ppm to 0-9,999 ppm
Calibration: 0-25%
3290​​Percent
0-1% to 0-25% (optional 0-100%)


​3300TA​
Micro-Fuel Cell (PPM)
​Two ranges with auto ranging capability
Field configurable:
0-10ppm to 0-10,000ppm

3300TB​Micro-Fuel Cell (PPM)
​Two ranges with auto ranging capability
Field configurable:
0-10ppm to 0-10,000ppm​

3350​
​Micro-Fuel Cell 
​0-25% oxygen

9060Z​
​Zirconium Oxide (ZrO2)
​0.01 ppm to 100%

InstaTrans-XD​​Micro-fuel Cell (Percent or ppm)
​0-10 ppm to 0-25%​



Oxygen Analyzers (Portable)​ ​ ​
​​
Model Technology ​Range(s)

​​
​3110​
Micro-fuel Cell (​Trace / Percent)
​0-10 ppm to 0-25%*

*third-party approved only for O2 levels below 20.9%
​3110P​
Micro-fuel Cell (Percent)
​0-1% to 0-2​5%*
(optional 0-100%*)

*third-party approved only for O2 levels below​ 20.9%
3110XL​
Micro-fuel Cell (​Trace / Percent)
​​0-2 ppm to 0-25%*​

*third-party approved only for O2 levels below 20.9%
​​​Back to Top​


Sulfur Analyzers ​ ​ ​

​Model ​Gases  Technology ​Range(s)

6200T​
Total Sulfur

​​UV-Fluorescence
​0-50 ppb (min)
0-20,000 ppb (max)



​​
6400T
Sulfur Dioxide (SO2​)

​UV-Fluorescence
0-50 ppb (min)
0-20,000 ppb (max)​
6400TH​
Sulfur Dioxide (SO2​)
​UV-Fluorescence
​0-10 ppm (min)
0-5,000 ppm (max)

6400TSG Total Sulfur ​UV-Fluorescence
PPB to percent levels,
application specific

​Back to Top​


Thermal Conductivity Analyzers ​ ​ ​

​Model Technology ​Range(s)

2000A​​Thermal Conductivity
​Per application

2000B​​Thermal Conductivity
Per application

2000XTC​​Thermal Conductivity
Per application

​2020​​Thermal Conductivity
Per applica​tion
 
2750​
​​Thermal Conductivity​
0-100% H2 in CO2
0-100% Air in CO2
80-100% H2 in Air 



​Back to Top



Tunable Diode Laser (TDL) Analyzers ​ ​ ​

​Model Gases Technology ​Range(s)




LGA-4000Z​Acetylene (​C2H2)
Ammonia (NH3)
Carbon Dioxide (CO2)
Carbon Monoxide (CO)
Ethylene (C2H4​)
Hydrogen Chloride (HCl)
Hydrofluoric Acid (HF)
Hydrogen Sulfide (H2S)
Methane (CH4)
Oxygen (O2)
Water (H2O)
​Tunable Diode Laser Spectroscopy (TDLAS)

​0-50 ppm to 0-100%
0-10 ppm to 0-100%
0-1,000 ppm to 0-100%
0-1,000 ppm to 0-100%
0-100 ppm to 0-100%
0-100 ppm to 0-50%
0-20 ppm to 0-50%
0-100 ppm to 0-100%
0-200 ppm to 0-100%
0-1% to 0-25%
0-100 ppm to 0-100%


Ultraviolet Analyzers ​ ​ ​
​Model Gases Technology ​Range(s)​

62​00T​Total Sulfur

​UV-Fluorescence
​​0-50 ppb (min)
0-20,000 ppb (max)

​​
​​
​6400T​Sulfur Dioxide (SO2​)

​​UV-Fluorescence
​0-50 ppb (min)
0-20,000 ppb (max)​

6400TH​

Sulfur Dioxide (SO2)​
​UV-Fluorescence​
​0-10 ppm (min)
0-5,000 ppm (max)

​​​Back to Top


​​