Liquid Analyzers​​
​> Alkalinity
> Colorimeters
> Liquid Chromatography
> Organics
> pH
Water Cut (BS&W)​
​> Ammonia / Ammonium
> Conductivity
> Nitrates
> ORP
Suspended Solids / Turbidity

​> Chlorine
> Hydrocarbon in Water
> Oil in Water
> Oxygen (Dissolved)
>​ Total Organic Carbon​


Alkalinity Analyzers ​ ​ ​


​Model Technology ​Range(s)
 ​

6800T​

​Titration​
​0-50, 50-200, 200-1,000, 0- >1,000 ppm or mg/l

Back to Top



Ammonia / Ammonium Analyzers ​ ​ 


​Model ​​Range(s) ​ ​

LXT-​330-NH4​

​0.05 - 18,000 ppm


Chlorine Analyzers ​ ​ ​


​Model ​Range(s)

CDA330

Chlorine:              0.05 - 20 ppm (High Range)
                              0.01 to 5 ppm (Low Range)
pH:                        0 to 14 pH​
FCA330Free ​Chlorine:     0.05 - 20 ppm
pH:                        0 to 14 pH

TCA​330​

​Total Chlorine:     0.05 - 20 ppm
pH:                         0 to 14 pH​


Colorimeters ​ ​ ​

​Model Method ​Range(s)
​ ​
CA​600​​​​​Photometric Differential Absorbance
​​Application Dependent


Conductivity ​ ​ ​


​Model ​Range(s)

​ ​
LXT-330
0.055 µS - 2 S (Units: µS. mS, S; Auto Ranging​)


LXT-380 Chlorine Dioxide:      0.01 - 20 ppm
Conductivity:              0.055 µS - 2 S (Units: µS. mS, S; Auto Ranging​)​

Dissolved Oxygen:    000.1 - 999.9 ppb, ppm, %S​AT, mg/L; Auto Ranging
ORP:                            -1,500 - +150 mV
pH:                               ​-1 - 15 pH​

pION:                          000.1 - 999.9 ppb, ppm, ppt, Auto Ranging
Resistivity:                  0.001 - 20 mega-ohms
Turbidity:                    0 - 4,000 NTU NTU, FNU, mg/L, ppm, % Solids,
                                     Auto Ranging
Temperature:            3 K-ohm TC, -22° to 284°F (-30° to 140°C)

Back to Top


Hydrocarbon In Water Analyzers ​ ​ ​


​Model ​Range(s)
 
4080​​​0-10, 0-100, 0-1,000 pppm
Other ranges available

6650SP​​Application Dependent

6700E​0-5 to 20,000 mg/L
Single or Dual Range with external diluter

6700U​

​Per configuration

Back to Top


Liquid Chromatography ​ ​

​Model Sampling Configurations Detectors​


Falcon GC​

Aspiration to inlet via sample pump​
​Process online via sample valve for gas or liquid*
Autosampler injections for liquid or heated headspace
Manual sy​ringe injection for gas or liquid



*Sample handling available
Dielectric Barrier Discharge (DBD)
​Flame Ionization (FID)

Flame Photometric (FPD)

Thermal Conductivity (TCD)


Back to Top


Nitrates Analyzers ​ ​

​Model ​Range(s)


LXT-330-N​
​0.1 - 1,000 ppm

Back to Top


Oil in Water Analyzer

​​

​Model ​Range(s)

4080​​
​​0-10, 0-100, 0-1,000 pppm
Other ranges available

6650SP​


​Application Dependent

6700E​
0-5 to 20,000 mg/L
Single or Dual Range with external diluter

6700U​
Per configuration

Back to Top


Organics Analyzer


​Model ​Range(s)
 
6700U​
Per Configuration

 Back to Top


Oxidation / Reduction Potential


​Model ​Range(s)
​ ​
LXT-330​-1500 - +1500 mV


LXT-380​

Chlorine Dioxide:      0.01 - 20 ppm
Conductivity:              0.055 µS - 2 S (Units: µS. mS, S; Auto Ranging​)​
Dissolved Oxygen:    000.1 - 999.9 ppb, ppm, %S​AT, mg/L; Auto Ranging
ORP:                            -1,500 - +150 mV​
pH:                               ​-1 - 15 pH​

pION:                          000.1 - 999.9 ppb, ppm, ppt, Auto Ranging
Resistivity:                  0.001 - 20 mega-ohms
Turbidity:                    0 - 4,000 NTU NTU, FNU, mg/L, ppm, % Solids,
                                     Auto Ranging
Temperature:            3 K-ohm TC, -22° to 284°F (-30° to 140°C)

Back to Top


Oxygen (Dissolved) Analyzers

​Model ​Range(s)

​ ​
LXT-330000.1 - 999.9 ppb, ppm, %SAT, mg/L; Auto Ranging


​LXT-380​

Chlorine Dioxide:      0.01 - 20 ppm
Conductivity:              0.055 µS - 2 S (Units: µS. mS, S; Auto Ranging​)​
Dissolved Oxygen:    000.1 - 999.9 ppb, ppm, %S​AT, mg/L; Auto Ranging
ORP:                            -1,500 - +150 mV​
pH:                               ​-1 - 15 pH​

pION:                          000.1 - 999.9 ppb, ppm, ppt, Auto Ranging
Resistivity:                  0.001 - 20 mega-ohms
Turbidity:                    0 - 4,000 NTU NTU, FNU, mg/L, ppm, % Solids,
                                     Auto Ranging
Temperature:            3 K-ohm TC, -22° to 284°F (-30° to 140°C)

Back to Top


pH

​Model ​Range(s)
​ ​
LXT-330​-1 - 15 pH​



LXT-380​

Chlorine Dioxide:      0.01 - 20 ppm
Conductivity:              0.055 µS - 2 S (Units: µS. mS, S; Auto Ranging​)​
Dissolved Oxygen:    000.1 - 999.9 ppb, ppm, %S​AT, mg/L; Auto Ranging
ORP:                            -1,500 - +150 mV​
pH:                               ​-1 - 15 pH​

pION:                          000.1 - 999.9 ppb, ppm, ppt, Auto Ranging
Resistivity:                  0.001 - 20 mega-ohms
Turbidity:                    0 - 4,000 NTU NTU, FNU, mg/L, ppm, % Solids,
                                     Auto Ranging
Temperature:            3 K-ohm TC, -22° to 284°F (-30° to 140°C)

Back to Top


Suspended Solids / Turbidity Analyzers


​Model ​Range(s)
​ ​

LXT-330​

0 - 4,000 NTU, FNU, mg/L, ppm, % Solids, Auto Ranging

Back to Top

Total Organic Carbon

​Model ​Range(s)
 
6700E​
​0-5 to 20,000 mg/L
Single or Dual Range with external diluter
​​
6700U
​Per Configuration

Back to Top


Water Cut / BS&W

​​Model ​Range(s)
​ ​
5650​
​0-25% to 0-100%

   ​​Back to Top​​


​​